A/D Mode Control Register - Omega Engineering OME-A8111 Hardware Manual

Isa-bus multi-functional board
Table of Contents

Advertisement

2.4.8 A/D Mode Control Register

(WRITE) Base+B : A/D Mode Control Register Format
Bit 7
Bit 6
X
SI2
X=don't care
Mode Select
D2 D1 D0
Software Trig
0
0
0
0
0
1
0
1
0
1
1
0
X=disable
SI2
SI1
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
The A/D conversion operation can be divided into 2 stages, trigger stage and transfer
stage. The trigger stage will generate a trigger signal to the A/D converter and the transfer
stage will transfer the results to the CPU.
The trigger method may be an internal trigger or an external trigger. The internal
trigger can be a software trigger or a pacer trigger. The software trigger is very simple
but can not control the sampling rate very precisely. In software trigger mode, the
program issues a software trigger command (sec. 2.4.9) any time needed. Then the program
will poll the A/D status bit until the ready bit is 0 (sec. 2.4.2).
OME-A-8111 Hardware Manual (ver.1.1, Jul/2003)
Bit 5
Bit 4
SI1
SI0
Trigger Type
Pacer Trig
Select
X
Select
X
X
Select
X
Select
SI0
IRQ Level
0
IRQ2
1
Not used
0
IRQ2
1
IRQ3
0
IRQ4
1
IRQ5
0
IRQ6
1
IRQ7
Bit 3
Bit 2
X
D2
Transfer Type
Software Interrupt
Select
Select
X
Select
Bit 1
Bit 0
D1
D0
X
X
X
Select
16