Rheem 874 Owner's Manual And Installation Instructions page 30

Gas continuous flow water heater
Table of Contents

Advertisement

TEMPERATURE CONTROL – DELUXE
BATH FILL MODE
The Bath Fill mode is designed to allow the water heater to deliver a selected volume of water at a selected
temperature. The Bath Fill mode commences when the BATH FILL button is on and a hot tap is opened.
When the set volume has been delivered, the water flow from the water heater ceases and heating stops. It
is also useful for controlling the water volume used by a shower or other application.
Note: The bath level should be monitored periodically while this function is in use to avoid the possibility of
the bath overflowing. The Bath Fill mode should be used with caution until you are familiar with its operation.
Warning: Baths should not be left unattended whenever young children are present. After using the
bath fill function, check the water temperature before entering a bath, to ensure it is suitable and will not
cause scald injury.
The Bath Fill mode can be set and turned off at any of the Deluxe controllers. Refer to the
Bath Fill Mode – Brief Guide
This guide provides a brief instruction on the operating sequence of the bath fill function. It is recommended
to read the explanatory notes and become familiar with each step in the bath fill function. Refer to
Mode – Explanatory Notes"
To operate the Bath Fill Mode:
1.
Turn off all Deluxe controllers
It is advised to turn off all Deluxe controller(s) before
activating the Bath Fill mode.
Refer to the notes on the
on page 28.
Pull down the front panel on the Deluxe controller.
2.
The BATH FILL VOLUME and BATH FILL TEMPERATURE
up () and down () buttons will be exposed.
3.
Set the Bath Fill temperature
Press the BATH FILL TEMPERATURE  (up button) or
the BATH FILL TEMPERATURE  (down button) to
select the desired bath fill temperature.
"Temperature Adjustment – Deluxe Controllers"
Refer to
on page 25.
The selected temperature setting will be displayed on all
Deluxe controllers.
4.
Set the bath fill water volume
Press the BATH FILL VOLUME  (up button) or the
BATH FILL VOLUME  (down button) to select the
desired bath fill water volume. Each press will change the
water volume setting by 10 litres.
Pressing the BATH FILL VOLUME  (up button) or
BATH FILL VOLUME (down button) continuously will
scroll the water volume setting.
A maximum volume of 990 litres and a minimum volume
of 10 litres can be set. The volume changes in 10 litre
increments.
The selected bath fill water volume will be displayed and
the bath fill indicator light will glow on all Deluxe
controllers.
on page 32.
Bathroom Deluxe controllers
8 8 8 8
B1
Bath Fill
Bath
Water
Volume
Set Bath Fill Water Volume
and Temperature
Hot Water
BATH (l)
"caution, bath fill water volume has
been increased, bath may overflow"
"bath fill water volume has been
30
notes
on page 36.
"Bath Fill
ACTIVE
°C
5 5
BATH (l)
BATH FILL
ON/OFF
Rheem
BATH FILL
BATH FILL
VOLUME
TEMPERATURE
1.
2.
3.
5.
7.
Bath Fill
Bath
completed
BATH FILL
BATH FILL
ACTIVE
Fill
(automatic)
Press Bath
Press Bath
Temp
Fill Button
Bath Fill Button
Fill Button
(Red light flashes)
(Red light on)
(R
ed light off)
°C
4. Open hot tap
6. Close hot tap
1 2 0
4 0
1.
2.
3.
4.
BATH (l)
ACTIVE
Adjust
Open hot
ON/OFF
Light on
Temperature
tap
Press
BATH FILL
ON/OFF
"hot water temperature has
been increased"
or
"hot water temperature has
been decreased"
ACTIVE
°C
1 2 0
4 0
BATH FILL
ON/OFF
or
decreased"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

872627

Table of Contents