2.3.4 JP4 : A/D Trigger Source Selection

Internal
Trigger
(default)
The OME-A-822PGL/PGH supports two trigger types, internal trigger and
external trigger. The external trigger comes from ExtTrg, CN3 pin 17.
There are two types of internal triggers, software trigger and pacer trigger.
More detailed information is given in section 2.4.8.

2.3.5 JP5 : Interrupt Level Selection

NO Interrupt
IRQ
Interrupt 15
(default)
IRQ
The interrupt channel can not be shared. The OME-A-822 software driver can support
8 different cards in one system but only 2 of these cards can use the interrupt transfer
function.
INTTRG
EXTTRG
3
4
5
6 7
3
4
5
6 7
OME-A-822PGL/PGH Hardware Manual ---- 13
External
INTTRG
Trigger
EXTTRG
9 10 11 12 14 15 NC
9 10 11 12 14 15 NC