Installation Instruction - Kemlan XL MK111 Installation & Operating Instructions Manual

Xl freestanding mk. iii
Table of Contents

Advertisement

1000mm minimum distance
above roof line or 600 minimum
above ridge if penetration
closer than 3 meters to ridge
Roof flashing supplied
by contractor
All casing flue pipes must
be connected w ith pop
rivets supplied by installer
Stainless steel flue pipe.
All flue pipes must be
connected w ith pop rivets
supplied by installer

INSTALLATION INSTRUCTION

INSTALLATION TO COMPLY WITH AS/NZS 2918
Stainless steel
A
double cone
cow l
10" Flue
8" Flue
Support outer flue
w ith angle bracket
supplied
B
6" Flue
Decroshield
FLAT CEILING
TRIPLE FLUE KIT
Support outer flue w ith
bracket supplied. Run a
bead of silicon dow n seam
of outer casing to ensure
against leaks.
Pop rivet or
screw brackets to
the outside of the
outer casing
Short tube fits into flue
pipe. All flues should
be trimmed level
Ceiling line
12mm min air gap
betw een ceiling line
and celling plate
Vented cap
Decroshield
NOTE:
When decromesh/heatsheild is fitted, it must finish a minimum 600mm below
the ceiling or extend through the ceiling drop box into the outer flue casing.
Alw ays cover flue completely until installation and cleanup is complete.
DETAIL A
25mm min
clearance
DETAIL B
10" Flue
8" Flue
150mm min