2. Installation location

A
Fig. 2-1

3. Installing the indoor unit

1
2
4
5
7
8
Fig. 3-1
B
A
A
F
75
B
F
226
Fig. 3-2
170(230)
80
A
Fig. 3-3
B
W
H
D
C
E
3
6
9
C
85
86
G
137
H
D
E
G H
C
180
H
200
G
E
241
B
(mm)
70
151(211)
A
Ø65
Ø100
125
C
B
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and mainte-
nance.
Models
W
D
50
1000
680
221
50GA2, 60, 71
1310
680
221
100
1310
680
281
125, 140
1620
680
281
Warning:
Mount the indoor unit on a ceiling strong enough to withstand the weight of the
unit.
2.2. Outline dimensions (Outdoor unit)
Refer to the outdoor unit installation manual.
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories (contained in the
inside of the intake grille).
Accessory name
1
Washer
2
Pipe cover
3
Pipe cover
4
Band
5
Joint socket
6
Socket cover
7
Drain tubing cover
8
Wired remote controller
RP50
RP60
9
Flare nut
RP100, 125, 140
RP71, P50-140
3.2. Preparation for installation (Fig. 3-2)
3.2.1. Suspension bolt installing spacing
Models
A
B
50
933
1000
50GA2, 60, 71
1240
1310
100
1240
1310
125, 140
1547
1620
3.2.2. Refrigerant and drain tubing location
Models
D
E
F
50, 60, 71
131
175
178
100, 125, 140
191
235
238
A Front side outlet
B Left side outlet
C Right side outlet
D Independent piece (Removable)
3.2.3. Selection of suspension bolts and tubing positions (Fig. 3-3)
Using the pattern paper provided for installation, select proper positions for suspen-
sion bolts and tubing and prepare relative holes.
A Pattern paper
B Suspension bolt hole
C Indoor unit width
Secure the suspension bolts or use angle stock braces or square timbers for bolt
installation.
A Use inserts of 100 kg to 150 kg each.
B Use suspension bolts of W3/8 or M10 in size
A
B
C
H
Min. 270
Min. 300
Min. 500
Min. 270
Min. 300
Min. 500
Min. 270
Min. 300
Min. 500
Min. 270
Min. 300
Min. 500
Q'ty
4 pcs
1 pc
Large size (For gas tubing)
1 pc
Small size (For liquid tubing)
4 pcs
1 pc
Marked with "UNIT"
1 pc
1 pc
1 pc
2 (ø9.52, ø15.88 )
1 (ø6.35)
1 (ø19.05)
0
(mm)
C
221
221
281
281
(mm)
G
H
J
K
L
90
82
159
156
90
150
142
219
216
150
E Right drain tubing
F Left drain tubing
G Gas tubing
H Liquid tubing
(mm)
E
Max. 250
Max. 250
Max. 250
Max. 250
3