Hardware Failures - Huawei AP3010DN-AGN Hardware Installation And Maintenance Manual

Hide thumbs Also See for AP3010DN-AGN:
Table of Contents

Advertisement

Huawei AP3x10xN&5x10xN&5x30xN&6x10xN&7x10xN
Hardware Installation and Maintenance Guide
4.1 A Device Fails to Be Powered On
Fault Description
The SYS indicator of a device is off.
Possible Causes
Power Supply Mode
Power supply using a power module
PoE power supply
Issue 11 (2015-05-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4

Hardware Failures

Possible Cause
l The power switch on the device is turned
off.
l The power cable is not securely connected
to the device.
l The power supply unit has failed.
– If the device connects to an external
power source, its power adapter may
fail.
– If the device has a built-in power
supply, the device itself may be faulty.
l The power sourcing equipment does not
support the PoE function or is faulty.
l The power sourcing equipment is
incorrectly configured (the PoE function
is disabled or the power-off time range is
improperly set).
l The line is faulty (the network cable or
distribution frame is damaged).
l The AP is faulty.