DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the appliance, first remove the exhaust filter cover
and filter.
- Remove the hinge lock-pin (see pictures).
- Remove the dustcover by simultaneously pushing the click
hook in the hinge and bending the hinge outside with a
screwdriver (see picture).
- To be able to remove the upper housing the cord outlet
must be removed using a screwdriver in the lower section
(see picture).
2
- After removing the 6 screws (A) the upper housing can be
removed.
- When the repair is finished, check whether all functions of
the appliance work properly.
- To disassemble the cord winder, use TORX screwdriver
no. T10, which is one of a set consisting of T20; T15; T10;
T9; T8; T7 and T6 (code number 4822 395 50145).

REPAIR INSTRUCTION

- The spare parts have been standardized as much as possible.
- Depending on the original cord, the spare cord must be
shortened to the length of the original cord.
- The cord winder spring must be tensioned to the maximum
level and then be rewound approx. 1.5 turn.
- Item 16, safety valve, opens to cool the motor if the air
displacement is too low or if the airflow is blocked.
- To prevent the switch getting damaged by too much force,
a protective ring (pos. 53) was added in the later versions.
If this part is missing it must still be placed as
modification!