Number Routing - Gaoke mg6008 Series User Manual

Table of Contents

Advertisement

5 FXS
Unchanged
6 FXS
Unchanged
7 FXS
Modified

5.1.10 Number routing

Number's route table's longest length is 100, and it is mainly used when there is no gatekeeper, the capacity
can basically satisfy the user needs.
MG6008 routing supports two kinds of route: SIP (by IP) and TEL connection.
The max length of phone number is 29, and the IAD supports to intercept length and extra prefix. When the
two options are valid, IAD will intercept the calling number and add the extra prefix in front
5.1.10.1 Add routing map
a). Configuration
IAD(8)#set gw-table
-> Please input phone number(prefix):12315
-> Is prefix'yes'or'no'[yes]:yes
-> Specify number length'yes'or'no'[yes]:yes
-> Number length[5]:5
-> Please input phone routing type(0-SIP;1-TEL)[0]:0
-> Please input routing IP address[0.0.0.0]:138.0.0.221
-> Peer gateway port(0-65535)[5060]:
-> Interception length of master phone routing [0]:3
-> Master phone routing need extra prefix'yes'or'no'[no]:yes
-> Number prefix:020
IAD(8)#set gw-table
-> Please input phone number(prefix):82598555
-> Is prefix'yes'or'no'[yes]:no
-> Please input phone routing type(0-SIP;1-TEL)[0]:0
-> Please input routing IP address[0.0.0.0]:138.0.0.221
-> Peer gateway port(0-65535)[5060]:
-> Interception length of master phone routing [0]:
-> Master phone routing need extra prefix'yes'or'no'[no]:
b). Display
IAD(8)#show gw-table
--------------------------------------------------------------------------------
No. |Prefix Code|Len |Type|IP Address
0
12315
1
82598555
--------------------------------------------------------------------------------
Total item:2
MG6000 Series Media Gateway User's Manual
1
|Port|Cut
5
SIP 138.0.0.221
8
SIP 138.0.0.221
020
|Extra Code |PhoneContext
5060 3
020
5060 0
- 78 -