After every repair, the unit has to be checked by an electrical specialist.
According to its design, the tool requires a minimum of care and maintenance.
However, the following maintenance works and component checks have to be
performed in regular intervals:
Clean the tool after completion of your work. Apply some grease onto the drilling
spindle thread. The ventilation slots must always be clean and unclogged.
Make sure that now water gets into the tool during cleaning.
After approx. 250 hours of operation, the carbon brushes must be checked and,
if necessary, be replaced by an authorized specialist (use only original carbon
brushes).
Once per quarter of a year, an electrical specialist should check the switch, cable
and plug.
SERVICE
Should you have any further queries, please phone one of the telephone numbers on
the last page of this manual.
SPIT takes no responsibility for machines that are not serviced, repaired or altered by a
workshop that is expressly permitted by SPIT to do so.
Dispose of your appliance, accessories and packaging in an environment-friendly
manner.
8