Restoring Factory Default Settings - impro XEC900 Installation Manual

Impro (ecii) ethernet controller
Table of Contents

Advertisement

Power Shut Down
II
The Impro EC
Controller's 6 V 3 Ahr Sealed Lead Acid Backup Battery provides
between 4-6 hours of uninterrupted power. Five minutes after the Battery Low signal's
received by the Controller, the Controller switches to Hibernation Mode (low power).
Hibernation Mode provides a further 48 hours of database (including transactions)
memory retention.
Master Reset
II
The Impro EC
Controller can be restarted manually, without removing the power
connections, by pressing the Master Reset button (See Figure 1 for Key Component
Positions).

Restoring Factory Default Settings

If you assign an invalid IP address to the Impro EC
communicate. Restore the Controller's factory default settings as follows:
CAUTION:
This will restore the firmware to the version set when shipped from
the factory. If you have upgraded the Controller's firmware since
installation, ensure that you upgrade again immediately.
1.
With power applied to the Impro EC
Factory Default Jumper Link (LK4). (See Figure 1 for Key Component Positions).
NOTE:
Take note of the Ethernet and CPU Diagnostic LEDs, the LEDs will switch
OFF then ON signaling that restoration has taken place.
2.
Remove the link.
Unit Address Information
Fixed Address Label
The last 8 digits of the MAC Address, that is 4A-9A-BC-3D (see Figure 7), translate to
the products Fixed Address used by the System Software.
Attach the loose Fixed Address Label (packaged with the Controller) in position on the
Unit Location Chart (or your sketched site plan).
MAC Address Label
II
Each Impro EC
Controller is supplied with a separate MAC Address Label, much like
the one shown in Figure 7, which uniquely identifies each Controller.
Attach the extra loose MAC Address Label, alongside the Fixed Address Label, to the
Unit Location Chart enclosed (or your sketched site plan).
XEC300-0-0-GB-09
II
Figure 7: Sample MAC Address Label
September 2015
II
Controller, it will not be able to
Controller, place a link across the pins of the
Page 14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ips970

Table of Contents