4-1-1 Wired Remocon Error Display(COM2)

•If an error occurs,
Display
Samsung Electronics
NS090SDXEA_E_SM_33623A(1)_1.indd 2
is displayed on the wired remote controller. If you would like to see an error code, press the Test button.
Explanation
Indoor unit Communication Error
Indoor/Outdoor unit Communication Time Out Error 60 Packet Over data
Indoor unit is not connected
Communication Error between Outdoor Main and Inverter Micom
(Occurred after 1 minute detection in Main and Inverter)
Indoor Temp. Sensor(Open/Short Error)
Indoor Unit Eva in Sensor(Open/Short Error)
Indoor Unit Eva in Sensor Separation
Outdoor Temp. Sensor Error(Open/Short Error)
COND Temp. Sensor Error(Open/Short Error)
Inverter Compressor Discharge Temp. sensor Error(Open/Short Error)
Power cable miss connection error
Indoor Float Switch 2nd Detection
Outdoor unit - indoor unit communication wire miss connection
(Connected to Power terminal)
Outdoor unit refrigerant Full leakage(Gas leak)
Outdoor Fan 1 Error
Outdoor Fan 2 Error
Discharge over temperature
[Inverter] Compressor starting error
Primary Current Over Trip error
[Inverter]IPM Over Current(O.C)
[Inverter] Compressor Rotation error
[Inverter] Current Sensor error
[Inverter] DC LINK Sensor error
[Inverter] EEPROM Read/Write Error
[Inverter] Heatsink temperature over Error
Outdoor unit Capacity Setup option error
Communication error between Indoor unit and wired remote control
Communication error between Master and Slave wired remote control
COM1/COM2 Cross-installed error
Error of setting option for wired remote control COM2
Troubleshooting
Remark
Communication Error
Indoor Sensor Error
Outdoor Sensor Error
Self Diagnosys Error
Outdoor UnitProtetion Control Error
Outdoor UnitProtetion Control Error
Wired remote control error
4-2
2011-04-08
10:54:56

Hide quick links: