Prerequistes; Building Notice; Combustion Air; Standard Delivery - KEDDY 100 Installation Instructions Manual

Table of Contents

Advertisement

PREREQUISITES

BUILDING NOTICE

When you install a stove and/or erect a chimney, you
may have to give building notice to the local Planning
and Building Committee. Contact the Planning and
Building Committee in your municipality for up-to-
date information.
FLUE
Inserts from Keddy must be connected to a flue
approved for at least 350ºC.
When connecting the insert to an existing flue one
must make sure that there are no leaks before instal-
lation. To ensure this you may contact your local
chimney sweeper or a suited proffesional before
starting the installation.
In order to enable a good function in your insert the
pressure (chimney draft) needs to be at least 12 pa
at nominell use. To ensure this we recommend that
the chimney should be at least 3,5 m and that the
flue has an area of 177 cm2.

COMBUSTION AIR

The combustion of wood requires air/supply air. The
inserts can be provided with an external air supply.
Mainly for properties with mechanical ventilation .
The main reason for using an external air supply is to
counter the underpressure that can arise in houses
with mechanical ventilation. Normally it is not neces-
sary to use external air supply, since the installation
takes place in an existing fireplace which is designed
to perform in the atmosphere of the house.
A sheet metal drum is used as an outdoor air duct.
The connection diameter of the supply air duct to
the stove is 100 mm. If the duct is more than 3 m
long, the diameter of the sheet metal drum must be
increased to 125 mm. (A stove's maximum need for
combustion air is approx. 20 m3/h)
The supply air must not be taken from crawl spaces.
If there is a crawl space, the sheet metal drum must
be extended to a valve in the foundation wall. If the
space is heated, the supply air channel must be insu-
lated against condensation.

STANDARD DELIVERY

1 st
Insert
1 st
Cast Iron foot 50 mm
2 st
Cast Iron feet 45 mm
1 st
Cast Iron handle
1 st
Fire Plate
1 st
Mineral wool
1 st
Joint glue
ACCESSORIE
1 st
Support leg

DIMENSIONS

(Measures in mm)
* Add 50 mm to the height due to the cast iron feet.
The illustrations below are depicting the models 103
and 203. All models in the 100 and 200-series have
the same measurments.
- 4 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

200

Table of Contents