11.2 Removal Procedure of Outdoor Unit

Steps
1.Remove big handle
Before disassamble.
Remove 1 connection screw fixing big
handleand then removethe big handle.
2. Remove top cover
Remove 3 connection screws among
top cover plate, front panel and right
sideplate. Then remove top cover
plate.
84
Warning: Be sure to wait for a minimum of 20 minutes after
turning off all power supplies and discharge the refrigerant
completely before removal.
Procedure
Top cover
Service Manual
Big handle
Installation and Maintenance