9.3 ALTERNATOR

A—VOLTAGE REGULATOR
B—BRUSH ASSEMBLY
Before removing rotor and stator, remove
brush assembly.
2 N•m (1.5 lb. ft.)
C—REAR BEARING CARRIER
D—MAIN WINDING TERMINAL BLOCK
E—STATOR
F—ROTOR
Install appropriate alternator removal tool
(special tool), hold flywheel, and torque tool to
48 N•m (35 lb. ft.).
Rotor can become damaged if not properly
supported. Place wooden block and rag
underneath rotor for support.
If torquing alternator removal tool does not
free rotor from crankshaft, tap end of tool with
brass hammer to loosen rotor.
To prevent eye injury, always wear
safety glasses or goggles when
using a hammer.
G—ALTERNATOR ENGINE ADAPTER
H—GROUND CABLE
I— EXCITER WINDING CONNECTOR
J—BRUSH ASSEMBLY
K—TERMINAL BLOCK
L—SLIP RINGS
M—FUEL CUTOUT CONNECTOR
N—VOLTAGE REGULATOR
Also known as Automatic Voltage Regulator or
AVR.