11-2-14 Compressor start error
1. Checklist :
1) Is the connection of cable for the compressor and power?
2) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
Is the restart error occurred again?
Is the interphase resistance value of
compressor (u↔v, v↔w, w↔u) normal?
interphase resistance insulated?
compressor and power terminal normal?
Samsung Electronics
141 Kinderkamack Rd, Park Ridge, NJ 07656 Tel: 201-782-1782 Fax: 201-782-1783 Web: www.amgair.com Email: info@amgair.com
Restart after power off.
Yes
Yes
Is the compressor body and
Yes
Is the connection cable for the
Yes
Exchange the PCB.
No
No
No
No
Correct the cable connection.
Air Marketing Group LLC
Terminate the service.
Exchange the compressor.
Exchange the compressor.
Troubleshooting
11-18