Note: In models with the fingerprint reader, the sensor is attached to the palm rest FRU. If the fingerprint
reader is defective, you can replace the palm rest by following the procedures in this section. The
replacement procedures are the same for a palm rest with or without a fingerprint reader.
Removal steps of palm rest or palm rest with fingerprint reader
Step
Screw (quantity)
1
M2 × 5 mm, flat-head, nylon-coated (13)
2
M2.5 × 5 mm, flat-head, nylon-coated (2)
3
M2 × 3 mm, flat-head, nylon-coated (1)
Step
Screw (quantity)
4
M2 × 5 mm, flat-head, nylon-coated (3)
Downloaded from LpManual.com Manuals
2
1
1
1
1
1
1
1
1
1
1
2
1
1
1
3
Color
Black
Black
Silver
Color
Black
.
Chapter 8
Removing and replacing a FRU
Torque
0.181 Nm
(1.85 kgf-cm)
0.181 Nm
(1.85 kgf-cm)
0.181 Nm
(1.85 kgf-cm)
Torque
0.181 Nm
(1.85 kgf-cm)
85