b) In the dry mode, if the ambient temperature ≥17℃(62℉), the compressor
will start.Then, the unit is controlled in the following manner: when the ambient
temperature ≤15℃(59℉), the compressor shuts down. When the ambient
temperature raise to be ≥17℃(62℉), the compressor starts again. The start
/stop of the compressor meets the requirement for 3-minute protection time.
c). Under the fan mode, fans runs on both high speed or low speed. Temperature
setting is in vain, unit just displays environment temperature between 10-35℃(50~95℉)
3) Timer setting
a) Upon start, press the Timer button to enter timed shutdown. Upon shutdown, press
this button to enter timed start. In the meanwhile, the timer indicator will illuminate.
b) Press the Timer button to enter the timing function (timed start/timed shutdown).
Adjust the up or down button to set the timing time. The time will cycle in the order of
1-2-3-......24-0-1 hours or 24-23-22-......1-0-24 hours. The
adjustment time of the timing function is relative time.
c) After timed start is set, once the timed start time is reached, the unit will start. In the
meanwhile, the timer indicator will extinguish and the ambient temperature is displayed.
d) After timed shutdown is set, once the timed shutdown time is reached, the unit will
shut down. In the meanwhile, the timer indicator will extinguish and the ambient temperature is displayed.
e) Only the last setting of the timing function is valid and valid once only.
f) ON/OFF operations caused by the button or remote control will clear all timing settings.
g) Once the timing is determined, if the timer button is pressed once, it is possible to
query the remaining timed start/shutdown time. If the timer button is pressed twice
continuously within 5s, it is possible to cancel timing.
6). The up button and down button may be used to change the set value of the temperature.
Two. Operation instructions of the remote control
The operation instructions of the buttons of this simple remote control are as follows:
1. Power button: press this button to turn on/off the unit;
2. Timer button: upon shutdown, press this button to set timed start; upon start, press
this button to set timed shutdown.
3. High button: press this button to allow the unit to operate in the high fan speed state
(except in the dry and sleep modes);
4. Low button: press this button to allow this unit to operate in the low fan speed state;
5. Up button: press this button to increase the temperature and timing value;
6. Down button: press this button to decrease the temperature and timing value;
7.℃ — F button: press this button to switch between the Celsius degree and Fahrenheit degree;
8. Cool button: press this button to set this unit to operate in the cooling mode;
9. Fan button: press this button to set this unit to operate in the air supply mode;
10. Dry button: press this button to set this unit to operate in the dry mode;
11. Sleep mode: press this button to set this unit to operate in the sleep mode.
Three. Multiple protection functions:
1. Anti-freeze protection function:
Upon cooling, when the compressors operates continuously for more than 10
minutes, if the pipe temperature Tp is less than or equal to 2℃ continuously for 20

Hide quick links: