Troubleshooting When Timer Lamp Blinks; Self-Diagnosis Lighting Mode - Hitachi RAK-25NH4 Service Manual

Room air conditioner
Hide thumbs Also See for RAK-25NH4:
Table of Contents

Advertisement

TROUBLESHOOTING WHEN TIMER LAMP BLINKS.

Model RAK-25NH4, RAK-35NH4, RAK-50NH4
Perform troubleshooting according to the number of times the indoor timer lamp and outdoor LD301 blink.

SELF-DIAGNOSIS LIGHTING MODE

Model: RAK-25NH4, RAK-35NH4, RAK-50NH4
No.
Blinking of Timer lamp
1
– – – – – – – –
5 sec.
2
– – – – – – – 2 times
5 sec.
3
5 sec.
4
5 sec.
5
5 sec.
6
5 sec.
1
5 sec.
7
(
– – Lights for 0.5 sec. at interval of 0.5 sec..)
5
sec.
<Cautions>
(1)
If the interface circuit is faulty when power is supplied, the self-diagnosis display will not be displayed.
(2)
If the indoor unit does not operate at all, check to see if the F-cable is connected or disconnected.
(3)
To check operation again when the timer lamp is blinking, you can use the remote control for operation
(except for mode mark
Reversing valve defective
When the indoor heat exchanger
temperature is too low in the
1 time
heating mode or it is too high in the
cooling mode.
Outdoor unit forced operation
When the outdoor unit is in forced
operation or balancing operation
after forced operation
Indoor/outdoor interface defective
– – – – – – 3 times
When the interface signal from the
outdoor unit is interrupted.
Outdoor electrical assembly
defective.
– – 4 times
Room thermistor or heat exchanger
thermistor is faulty
– – 9 times
When room thermistor or heat
exchanger thermistor is opened
circuit or short circuit.
Over-current detection at the DC fan
motor
– – 10 times
when over-current is detected at the
DC fan motor of the indoor unit.
IC401 or IC402 data reading error
– – 13 times
When data read from IC401 or
IC402 is incorrect.
1).
Reason for indication
– 99 –
Possible cause
(1) Reversing valve defective
(2) Heat exchanger thermistor
disconnected
(only in the heating mode)
(Note)
The malfunction mode is entered the
3rd time this abnormal indication
appears (read every 3 minutes).
Electrical parts in the outdoor unit
(1) Indoor interface circuit
(2) Outdoor interface circuit
Please check at the outdoor
electrical led lamp blinking (LD301)
and refer to self diagnosis lighting
mode for outdoor unit.
(1) Room thermistor
(2) Heat exchanger thermistor
(1) Indoor fan locked
(2) Indoor fan motor
(3) Indoor control P.W.B.
IC401 or IC402 abnormal