General Information - Napoleon XIR3N Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

6
A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
EN
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
2.4

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Max. Output (BTU/HR)
Efficiency (w/the fan on)
A.F.U.E. (maximum value)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation
in a mobile home that is permanently positioned on its site and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
W415-1343 / 10.07.14
www.nficertified.org
XIR3
NG
0-4,500
31,000
24,800
80%
77%
4.5"(11mb) WC
7"(17mb) WC
3.5"(9mb) WC
67.0%
XIR3
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
4.12A
LP
0-4,500
31,000
24,800
80%
77%
11"(27mb) WC
13"(32mb) WC
10"(25mb) WC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xir3p

Table of Contents