3. Open the iris completely. If an autoiris lens used, reduce the room lighting to allow the lens to open
completely. This gives the most accurate results.
4. Zoom the lens in to the maximum telephoto setting. Adjust the optical focus of the lens using the
remote lens control.
5. Zoom out to the maximum wide angle setting. If the picture is no longer in focus, readjust the
backfocus screw.
6. Repeat steps 4~6 until the image remains sharp through the entire zoom range.
This completes the adjustment. The backfocus adjustment screw is held in place by friction, so there
is no locking screw.
13. CAMERA MOUNTING HOLE
There are two mounting holes provided, one each on the top and bottom of the camera.
OSD MENU SET UP FOR VN-855WDRV5 CAMERA
Settings for the VN-855WDRV4 camera can also be done from an OSD menu system after the camera is
setup in the ViconNet system (ViconNet setup procedure follows). Refer to the most current ViconNet
manual, XX113-0X, for detailed instructions on using ViconNet.
Configuration of the VN-855WDR is done through the ViconNet GUI. Prerequisites for using this procedure
with the VN-855WDR are ViconNet version 4 and higher, ViconNet driver 914 and higher and VN-855WDR
installed with version 4.3.1.0 or higher.
Make sure the proper driver is installed. The driver is found in ViconNet/VNVer/Drivers/Controls. The
driver is ViconMenu.dll. The VN-855VDR camera must be initialized and connected to ViconNet.
Note: The VN-855WDR has a Mode Selection DIP Switch. Make sure this is set to ON for WDR.
1. Select the camera. From the ViconNet GUI, select the Controls button in the Other Controls area. Refer
to Figure below.