Download Print this page

IDEAL Logic ES24 Installation And Servicing page 30

Hide thumbs Also See for Logic ES24:

Advertisement

25 ele Ct RiCAl Conne Ction S
Warning. This appliance
A mains supply of 230Vac ~ 50 Hz is required.
The fuse rating should be 3A. All external controls and wiring
must be suitable for mains voltage.
Wiring external to the boiler MUST be in accordance with the
current I.E.E. (BS.7671) Wiring Regulations and any local
regulations.
30
inStAllAtion
MUST be earthed.
Wiring should be 3 core PVC insulated cable, not less than
0.75mm
2
(24 x 0.2mm), and to BS 6500 Table 16. For IE
reference should be made to the current ETCI rules for
electrical installations.
Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles. The
means of isolation must be accessible to the user after
installation.
Logic Combi ES -
Installation and Servicing

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Es35Es30