Nortel Contivity Secure IP Services Gateway 4600 Owner's Manual page 8

Fips 140-1 non-proprietary cryptographic module security policy
Hide thumbs Also See for Contivity Secure IP Services Gateway 4600:
Table of Contents

Advertisement

Once the Extranet Switch has been configured in its FIPS 140-1 level 2 mode, the cover
may not be removed without signs of tampering. To seal the cover, apply three serialized
tamper-evident labels as follows:
1. Clean the cover of any grease, dirt, or oil before applying the tamper-evident labels.
Alcohol based cleaning pads are recommended for this purpose. The temperature of
the switch should be above 10 C.
2. Apply two (2) labels on the top cover overlapping the side and the rear of the chassis
as shown in Figure 5.
3. Apply two (2) labels on the top and bottom overlapping the front bezel as shown in
Figure 5.
4. Apply one (1) label over the keyboard button cover as shown in Figure 5.
5. Record the serial numbers of the labels applied to the module.
6. Allow 24 hours for the adhesive in the tamper-evident seals to completely cure.
Figure 4 – Front view without front bezel
8