Indoor Unit Installation; Installation Plate Mounting; Drill A Hole In The Wall; Connective Pipe Installation - Midea CS337I-BPMB Installation Manual

Room air conditioner
Table of Contents

Advertisement

INDOOR UNIT INSTALLATION

INDOOR UNIT INSTALLAITON
Remove the installation plate from
the indoor unit.The installation plate
should be installed on a wall which can
support the weight of the indoor unit.

1. Installation Plate Mounting

1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five 5mm diameter
holes in the wall and insert Clip
anchor for appropriate mounting
screws.
3. Secure the installation plate to the
wall with screws.
NOTE:
Mount the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate provided
with the machine differ from appliance
Left rear side
refrigerant
to appliance.
pipe hole
(Dimensions are in mm unless
"
"
otherwise stated)
The installation plate is fixed with a screw
for the convenience of shipment, please
remove the screw first before installation.
Left rear side
refrigerant
pipe hole
209
184
101
136
Left rear side
refrigerant
pipe hole
65
730
Model A
182
128
Left rear side
refrigerant
pipe hole
65
810
Model B
581
172
242
53.5
76
40
144
98
138
34
29
43
59
12
65
980
Model C
581
219
300
53.5
76
53.5
151
148.7
44.7
174.3
15.3
47
47
15.3
65
1090
Model D
Fig.2
5 5

2. Drill a hole in the wall

Indoor unit
1. Determine hole positions according to left
outline
and right side of the installation plate. The hole
center is obtained by measuring the distance as
shown in the diagram of Fig.2.
2. Dirll the piping plate hole with
Right rear side
refrigerant pipe
3. Drill the piping hole at either the right or the left and
hole
65
the hole should be slightly slanted to the outdoor side,
so that the outside end is lower than inside end,see Fig.3.
4. Always take steps to protect the pipe when drilling
Indoor unit
metal grid,metal plate or the like.
outline

3. Connective pipe installation

1. For the left-hand and right-hand piping,
remove the pipe cover from the side panel.
2. For the right back and left back piping,
Right rear side
refrigerant pipe
install the piping as shown.
hole
65
NOTE:
Both sides drainage structure is
standard. For both sides drainage structure,
it can be choosen for right, left or both sides
drainage connection. If choosing both sides
Indoor unit
drainage connection, another proper drain
outline
hose is needed as there is only one drain
hose offered by factory. If choosing one side
drainage connection, make sure the drain
hole on the other side is well plugged.
Right rear side
refrigerant pipe
For 9k/12k models, if choosing left-hand
hole
65
or left-back piping,please choosing left side
drainage connection. The connection of the
drain hose is supposed to be done by
qualified installer in case of water leakage.
3. Attach the drain hose to the underside of
Indoor unit
outline
the refrigerant pipes with adhesive viny
tape.
4. Wrap the refrigerant pipes and drain hose
together with insulation tape.
5. Open the front panel, then open the wire
Right rear side
refrigerant pipe
cover, connecting the cables.
hole
65
6. Bundle the pipes, connecting cable, and
drain hose with tape securely, evenly as
shown in Figure on the right.
7. Pass them through the wall hole.
Because the condensed water from rear
of the indoor unit is gathered in ponding
box and is piped out of room. Do not put
anything else in the box.
INDOOR UNIT INSTALLATION
Wall
Indoor
65mm hole-core drill.
Fig.3
Fig.4
Fig.5
6 6
Outdoor
Rubber plug