971
LONER
high performance
Temperature Controlled
Soldering Station
Loosen RCS71
Collar by turning
counter-clockwise
and pull the Tip
straight out.
Temp. Regulation
Indicator
Temp. Control
TIP CARE
1. Set desired temperature. Blinking
Lamp means Tool is regulating.
2. TIN the Tip. (apply solder)
3. Do not rub, bend or reshape the Tip.
4. Always clean the Tip by wiping it
against the saturated sponge and
always RE-TIN.
TEMPERATURE CALIBRATION
AIR MOVEMENT WILL AFFECT THE TEMPERATURE READING.
WORK IN AN AREA WHERE THIS IS MINIMAL.
1. Turn on power
and set Temperature
Control Knob to 400°F.
2. Using a clean and well tinned Tip,
apply a small amount of solder on the
Tip, just enough to form a bead on top
of the Tip.
3. Place the center of the thermocouple
wire of the SDS100 on top of the bead.
4. Again, apply a small amount of solder
on the center of the thermo-couple
wire, just enough to embed the center.
5. Adjust LO-Temp. Calibration Pot so the
Meter will read 400°F.
6. Set Temperature Control Knob to 800°F.
7. Adjust Hi-Temp. Calibration Pot so the
Meter will read 800°F.
®
To replace Pod,
press Release Tab
and slide out Pod.
Direct Tip/Heater
Contact
Sponge Holder
SPECIFICATIONS
• 120V, 50/60Hz, 70W, 2.5 lbs. (1.13 kg.)
• COMPLIES WITH DOD-STD-2000-1B, MIL-STD-
2000A and ESD SPEC. DOD-STD 1868, DOD-
HDBK-263
• TEMP. RANGE: 400°F - 800°F (205°C - 427°C)
• TEMP. REGULATION: ±6°F (±3°C)
• TIP TO GROUND LEAKAGE: < 2MV
• TIP TO GROUND RESISTANCE: < 2 OHMS
• UL LISTED
Hi/Lo Temp. Calibration Pot
WARNING: DO NOT HIT OR TAP THE
TOOL. HEATER ELEMENT WILL BREAK!!!
FX635
Power Switch
MS412
Temperature
Calibration System
m a d e
in
U S A
Static Safe
PD528
Tool Pod
SDS100
Need help?
Do you have a question about the 971 LONER and is the answer not in the manual?
Questions and answers