1. PRINCIPLE OF OPERATION

A. Combustion System
(1) The combustion system is based on a fully modulating forced draft combustion air
blower, a negative pressure regulated gas valve, and a 100% premix burner. On a
call for humidity, the combustion air blower starts and creates a negative pressure
across an orifice located at the air inlet.
(2) The blower is energized to purge the system, then the hot surface igniter is activated.
During this time the electronic ignition module does a diagnostic check of safety
systems including the air-proving switch, which senses the negative pressure at the
air inlet orifice. After the function of the safety systems has been verified, the gas
valve will open and the gas/air mixture is ignited by the hot surface igniter.
(3) If a flame is sensed by the flame sensor, the gas valve remains open and
combustion continues. If a flame is not sensed, the above sequence is repeated to a
maximum of three times after which the ignition module will lock out. The gas valve
maintains a constant ratio air to gas independent of blower speed or external
conditions. This air and fuel is thoroughly mixed in the blower and then forced
through the burner ports where ignition occurs.
(4) Hot products of combustion are forced through a baffle inside the heat exchanger
and then vented outside. The heat exchanger has a large flat surface to minimize
scale build-up and promote scale shedding to the bottom of the tank. This self-
cleaning action helps to maintain the efficiency of the heat exchanger while the
smooth surfaces allow for easy cleaning when necessary.
(5) The GS 100 has a single removable combustion chamber/heat exchanger. The
combustion system is duplicated on larger units with multiple chambers inside a
common tank.
SPECIFICATION
Rated Capacity: lbs/hr*
Rated Capacity: kg/hr*
Input BTU/hr max
Input kJ/hr max
Flue Emissions
GSTC/GSP Rated Amps
Voltage/Phase
GSTC Outdoor Rated Amps
Voltage/Phase
GSTC/GSP Rated Amps
Voltage/Phase
GSTC Outdoor Rated Amps
Voltage/Phase
Table 1. Technical Data
GS 100
GS 200
25-105
25-210
11-48
11-95
140,000
280,000
41
82
Low CO (< 10 ppm) and Low (NOx <40 ppm)
1.1
1.9
3.2
4.0
2.1
3.7
6.3
7.4
UNIT TYPE
GS 500
GS 300
GS 400
25-525
25-315
25-420
11-238
11-143
11-191
700,000
420,000
560,000
206
124
165
2.7
3.5
208-240/1 Standard
6.9
7.7
208-240/1 Standard
5.3
6.8
120/1 Standard
13.7
15.2
120/1 Standard
GS 600
25-630
11-286
840,000
247
5.2
4.3
11.5
10.6
10
8.4
22.6
21.0
10-00
Page 2
2008-10-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs series gstc indoorGstcGsp

Table of Contents