11 Hotel mode

1. Purpose
Restrict a function for hotels.
2. Access command
· Enter to the Service Mode.
· Press MUTE button on remote control. Hold few
seconds.
· Press the ch "UP" or "Down" button and Vol. "UP" or
"Down" button to Set the data of EEPROM(ADDRESS
1584) to 01.
Push the Power switch(button) off/on the set(the remote
control) to turn the set off/on.
It can be made Hotel mode.
3. Exit command
· First, set the data of EEPROM (ADDRESS 1584) to 00.
Next, Push the Power switch(button) off/on the set(the
remote control) to turn the set off/on.
Then, it is no longer hotel mode.
4. Access command to the Hotel mode setup menu
· <Prerequisite> : It is conditions that the data of
EEPROM(ADDRESS 1584) is 01.
In order to display the Hotel mode setup menu, please
enter the following command (within 2 second).
[TV] : Vol. "Down" + [REMOTE] : TV/VIDEO (3 times)
Then, the Hotel mode setup menu is displayed.
5. Explain the Hotel mode setup menu
CAUTION
This setup is not valid, unless data of EEPROM
(ADDRESS 1584) will be 01, even if each settings were
done.
item
Mode
Select hotel mode ON/OFF
Input
Select input signal modes.
Set this signal, each time power is switched
on.
<Selection> :
Off/RF/COMP1/COMP2/HDMI1/HDMI2/VID
EO1/VIDEO2
· Off: give priority to a last memory.
Channel
Select channel when input signal is RF.
Set the channel, each time power is switched
on.
<Selection>:0 to Last setting value
Volume
Adjust output Volume.
Set this volume, each time power is switched
on.
If the value of InitVol is changed, volume will
change. However, priority is given to a last
memory when InitVol is Off. When "InitVol" is
larger than "MaxVol", make "InitVol" and
"MaxVol" the same.
<Selection/Range> :
Off/0 to 63
· Off: give priority to a last memory
Vol. Max
Adjust maximum volume.
Set this max. volume, each time power is
switched on.
When "MaxVol" is smaller than "InitVol",
make "MaxVol" and "InitVol" the same, if
"InitVol" is not Off.
<Range> :
0 to 63
OSD Ctrl
Restrict the OSD.
Restrict the OSD, each time power is
switched on.
<Selection>:Off: altogether valid.
Pattern1: restrict the OSD.
FP Ctrl
Select flont key conditions.
Set this condition, each time power is
switched on.
<Selection> :
Off/Pattern1/All
· Off: altogether valid
· Pattern: restrict input selection
· All: altogether invalid.
Pow Ctrl
Select power on control when AC power on.
Off: Power on in the state of last.
ON: Power on when AC power on.