Download Print this page

How To Order Repair Parts - Berko FRA series Installation And Maintenance Instructions

Fan forced

Advertisement

Operation
1. Rotate the thermostat fully clockwise. This should
energize the heating elements and cause warm air to
flow from the hot air discharge at the openings in the bot-
tom of the grille.
NOTE: This heater is provided with a fan delay control that
allows the heating element to warm prior to the fan coming
on. This delay will also allow the fan to operate for a short
period after the heating element has been turned off to
remove the residual heat from the heater.
2. After the operation check, rotate the thermostat to
the desired position to obtain room comfort.
NOTE: For best results, the heater should be left "ON"
constantly during the heating season because the thermo-
stat, when properly set, will maintain the desired tempera-
ture.
Important Information
FRA40203
MODEL NO.
FAN FORCED WALL HEATER
APPAREIL DE CHAUFFAGE MURAL À AIR PLUSÉ
VOLTS AC
60HZ
WATTS
HI LO
208
4800
MUST BE USED WITH AWH-BB BACK BOX
DO NOT OPERATE WITHOUT FRONT COVER IN PLACE.
DOIT ÉTRE UTILISÉ AVEC BOÎTIER ARRIÈRE AWH-BB
NE PAS UTILISER SI LE COUVERCLE AVANT N'EST PAS EN PLACE.
MARLEY ENGINEERED PRODUCTS
BENNETTSVILLE, SC 29512
Maintenance
TO RESET MANUAL RESET LIMIT
Your heater is equipped with a manual reset safety thermal
limit control that will automatically turn the heater off to pre-
vent a fire if the heater overheats. This control is located on
the fan panel assembly between the element and fan blade
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except
heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage
from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or
maintained in violation of the product's installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return prod-
ucts to Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized ser-
vice center or the Marley Engineered Products Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed
that such repair or replacement is the exclusive remedy available from Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED
FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state.
For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the
factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return autho-
rization, include all catalog numbers shown on the products.

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement
parts, warranty service or technical information, please
contact Marley Engineered Products Service Center toll-
free by calling 1-800-642-HEAT.
When ordering repair parts, always give the informa-
tion listed as follows:
1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture
Part No. 5200-2264-000
0695
DATE CODE:
PHASE
3
7746 LISTED
ROOM HEATER
LIMITED WARRANTY
SWO 244
07/95
4
and marked "reset". The red reset button can be seen
through the front grille when the heater is installed. To reset,
allow the heater to cool, then push the red button that is vis-
ible through the hole in the fan panel. The heater should
immediately return to normal operation.
CAUTION
OPERATION OF THE MANUAL RESET SAFETY THERMAL LIMIT
CONTROL IS AN INDICATION THAT THE HEATER HAS BEEN
SUBJECTED TO SOME ABNORMAL CONDITION. IT IS RECOM-
MENDED THAT THE HEATER BE CHECKED BY A REPUTABLE
ELECTRICIAN OR REPAIR SERVICE TO ENSURE THE HEATER
HAS NOT BEEN DAMAGED.
Once each year the heater should be cleaned to remove dust
and other foreign material which has collected during the
heating season. This is a simple operation when performed
as follows:
1. Turn off the electric power at main line switch (or remove
all fuses) to disconnect electric power from the heater.
THIS IS IMPORTANT.
2. Remove thermostat knob.
3. Remove front cover by depressing plastic snap tabs with
a flat bladed screw driver as shown in Figure 5. Release
both tabs on one side then rotate the front cover off of the
fan deck.
4. With a vacuum cleaner nozzle or dust cloth, remove dust
and other foreign material.
5. After cleaning, turn disconnect switch to ON position and
reinstall the grille.
6. Turn on the main line switch (or replace fuses) to restore
power to the heater. The heater is now ready for another
season of operation.
CAUTION
DO NOT USE WATER OR DAMP CLOTH FOR CLEANING AND
DO NOT DISTURB THE HEATING ELEMENT.
!
!
SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA

Advertisement