Boiler Location & Clearances - Worcester Greenstar Heatslave II External 12/18 Instruction Manual

Floor standing oil fired condensing combination boiler conventional flue & room sealed flue
Hide thumbs Also See for Greenstar Heatslave II External 12/18:
Table of Contents

Advertisement

600mm
600mm min
2500mm
85mm
2500mm
INSTALLATION & SERVICING INSTRUCTIONS FOR GREENSTAR HEATSLAVE II EXTERNAL 12/18-18/25-25/32
6 720 805 210-01
600mm
BASE
Plan
45mm
view
FRONT
600mm
50mm
10mm
Plan
view
FRONT
BOILER LOCATION &
CLEARANCES
WARNING:
This appliance should not be installed where
there is a potential for excessive ground
water coverage.
This boiler is only suitable for installing
externally at a suitable location onto a fixed
permanent rigid surface c apable of
supporting the boiler weight.
2500mm
There must be a sufficient hard standing
around the appliance to allow for servicing.
The boiler must be installed on a flat level
surface to ensure that condensate does not
enter the primary heat exchanger.
Tarmac and wood hardstandings are not
recommended.
CLEARANCES: Min service & flue clearances
Above
Front
RH/LH clearance flue outlet on opposite side: 10mm
RH clearance flue outlet on rear:
LH clearance flue outlet on rear:
Rear clearance flue outlet on side:
Rear clearance flue outlet on rear:
It is strongly recommended that the flue
terminal faces away from walls to reduce the
possibility of wetting occuring.
50mm
10mm
Plan
view
FRONT
600mm
600mm
45mm
85mm
50mm
2500mm
BOILER LOCATION &
CLEARANCES
17