Refrigerant System Diagram - Fujitsu ASYA12LCC Service Manual

Wall mounted type
Hide thumbs Also See for ASYA12LCC:
Table of Contents

Advertisement

REFRIGERANT SYSTEM DIAGRAM

Models : ASYA12LCC / AOYR12LCC
Muffler
Refrigerant pipe diameter
Liquid : 1/4" (6.35 mm)
Gas : 3/8" (9.52 mm)
2005.12.16
3-Way
valve
4-Way valve
Cooling
Heating
Heat exchanger
( INDOOR )
Heat exchanger
( OUTDOOR )
3
2-Way
valve
Strainer
Expansion valve
Strainer