Panasonic KX-TH1211B Service Manual page 65

Telephone equipment
Hide thumbs Also See for KX-TH1211B:
Table of Contents

Advertisement

10.1.4.3. Check Table for RF part
No.
Item
1
Link Confirmation Normal
HS, BU Mode [Normal Mode]
2
Control signal confirmation
HS, BU Mode: [Normal Mode] (*1)
3
'
X
tal Frequency confirmation (*8)
HS, BU Mode: [Adjustment] (*4)
4-1 TX confirmation
Regular HS Mode:
[Test RX_CW Mode] (*5)
↑ [AIR]
BU (to be checked) Mode:
[Normal Mode]
4-2 TX confirmation
Regular BU Mode:
[Normal Mode]
↑ [AIR]
HS (to be checked) Mode:
[TEST TX_CW Mode] (*5)
5-1 RX confirmation
Regular HS Mode:
[Test TX_CW Mode] (*5)
↓ [AIR]
BU (to be checked) Mode:
[Normal Mode]
5-2 RX confirmation
Regular BU Mode:
[Normal Mode]
↓ [AIR]
HS (to be checked) Mode:
[TEST RX_CW Mode] (*5)
6
Range Confirmation Normal
HS, BU Mode: [Normal Mode]
Note:
(*1)(*4)(*5) Adjustment and Test Mode Flow Chart (P.51)
(*2)(*3) RF-DSP Interface Signal Wave Form (P.67)
(*6) Handset Reference Drawing (P.98)
(*7) Base Unit Reference Drawing (P.97)
(*8) Things to Do after Replacing IC or X'tal (P.93)
BU (Base Unit) Check
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
Check DSP interface. (*2)
'
Check X
tal Frequency.
(13.824000 MHz ±100 Hz)
1. Place Regular HS 15 cm away from a
checked BU.
2. Confirm "RXDATA" waveform of Regular
HS by Oscilloscope.
Please try to vary Regular HS CH from 00
ch to 04 ch to be matched to the BU
dummy CH, then the waveform is verified.
(*6)
1. Place Regular HS 15cm away from a
checked BU.
2. Confirm "RXDATA" waveform of the BU by
Oscilloscope. (*7)
When the BU scans TX_CW, RXDATA is
LOW.
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
3. Compare the range of the BU (being
checked) with that of the Regular BU.
65
KX-TH1211B/KX-TH1212B/KX-TGA930T
HS (Handset) Check
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
Check DSP interface. (*3)
Check signal at power-on.
'
Check X
tal Frequency.
(13.824000 MHz ±100 Hz)
1. Place Regular BU 15 cm away from a
checked HS.
2. Confirm "RXDATA" waveform of Regular
BU by Oscilloscope. (*7)
When Regular BU scans TX_CW, RXDATA
is LOW.
1. Place Regular BU 15 cm away from a
checked HS.
2. Confirm "RXDATA" waveform of the HS by
Oscilloscope.
Please try to vary the HS CH from 00 ch to
04 ch to be matched to Regular BU dummy
CH, then the waveform is verified. (*6)
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
3. Compare the range of the HS (being
checked) with that of the Regular HS.