SPECIFICATIONS

Part Number:
Blower:
Power:
Supply Voltage:
Current Draw:
Circuit Requirement:
Energy Factor:
Operating Range:
Sized for:
Minimum Performance at:
Water Removal:
Efficiency:
Duct Connections:
Air Filter:
Efficiency:
Size:
Optional Air Filter:
Efficiency:
Size:
Power Cord:
Internal Insulated Cabinet: Yes
Drain Connection:
Refrigerant Type:
Refrigerant Amount:
Dimensions:
Width:
Height:
Length:
Weight:
FRONT
20 1/4"
6" Diameter
10" Diameter
10" Diameter
4
Ultra-Aire XT205H Installation Instructions
4031560
526 CFM @ 0.0" WG
495 CFM @ 0.2" WG
458 CFM @ 0.4" WG
1525 Watts @ 80°F and 60% RH
115 VAC – 1phase – 60 Hz
13.2 Amps
20 Amp Dedicated
2.7 L/kWh
56°F Min, 95°F Max (Inlet Air Temperature)
Up to 5,000 Sq. Ft. - Typical
80°F and 60% RH
205 pints/day
5.7 Pints/kWh
6" Round Inlet; 10" Round Inlet; 10" Oval Outlet
MERV-11, Standard Pleat
65% ASHRAE Dust Spot
16" x 20" x 2"
MERV-14, Embossed Pleat (will need filter housing)
95% ASHRAE Dust Spot
20" x 24" x 4"
9', 115VAC, Ground
3/4" Threaded Female NPT
R410A (Refer to manufacturers label for more information)
2 lbs., 1 oz.
Unit With Collars
20 1/4"
21 3/4"
41 1/2"
140 lbs.
41 1/2"
37 3/4"
70°F and 60% RH
153 pints/day
5.0 Pints/kWh
Unit Without Collars
20 1/4"
21 3/4"
37 3/4"
139 lbs.
www.Ultra-Aire.com | 1-800-533-7533
Shipping
25"
28"
42"
173 lbs.