Summary of Contents for BK Precision 2831D

  • Page 1: Instruction Manual

    Instruction Manual Model 2831D 4 ½ Digit True RMS Digital Multimeter...
  • Page 2: Table Of Contents

    CONTENTS 1. PRODUCT DESCRIPTION 1-1. Introduction --------------------------------------------------------- ( 3 ) 1-2. Technical Specifications ---------------------------------------- ( 6 ) 1-3. Equipment Ratings ----------------------------------------------- ( 8 ) 1-4. Supplied Accessories -------------------------------------------- ( 9 ) 1-5. International electrical Symbol -------------------------------- ( 9 ) 2. INSTALLATION 2-1.
  • Page 3: Product Description

    1. PRODUCT DESCRIPTION 1-1. Introduction Thank you for purchasing our product. Electronic measuring instruments produced by us are high technology products made under strict quality control. We guarantee their exceptional precision and utmost reliability. For proper use of the p roduct, please read this operation manual carefully.
  • Page 4: Input Terminal

    1 0 0 0 V M A X . 1 5 s e c 1 2 0 0 V E A C H 1 5 m i n . 20A MAX FUSED k H z POWER 5 0 0 V FUSED 2 0 0 0 m A M A X O F F...
  • Page 5 ? 2000 DC 1200V/AC1000V, 2000mA,2000 kohm n Input Terminal Limits Input Switch Min. Display Max. Display Maximum Terminals Function Reading Reading Input Black DC V VΩHz COM 0.0001V 1200.0V 1200Vdc, AC V VΩHz COM 0.0001V 1000.0V 1000 Vac VΩHz COM 0.0001kΩ...
  • Page 6: Technical Specifications

    GROUND TERMINAL 1-2 Technical Specification Important Note: All accuracies apply to 5% to 95% full scale of each range - DC VOLT Range Resolution Accuracy Impedance 100 uV ±(0.05% + 5d) 20 V 1 mV 10 MΩ 200 V 10 mV ±(0.1% + 5d) 1000V 100m V...
  • Page 7 - DC CURRENT Range Resolution Accuracy Over Load Protection 2 mA 100 nA ±(0.75% + 5d) 20 mA 1 uA 2A/250V 200 mA 10 uA ±(1.0% + 5d) 100 uA ±(1.0 % + 10d) 20 A 1 mA 15A/250V 20A Range for 15 seconds max during each 15 minute period - AC CURRENT Over Load Range...
  • Page 8: Equipment Ratings

    - RESISTANCE Range Resolution Accuracy Over Load Protection 0.1 O 2 KO 20 KO ±(0.2% + 5d) 10 O 200 KO 600V DC or Peak 100 O 2 MO ±(1% + 10d) 20 MO 1 KO - FREQUENCY Range Resolution Accuracy Over Load Protection ±(1.0% + 5d)
  • Page 9: Supplied Accessories

    103 ∼ 126V AC (50/60Hz) F 0.5A / 250V 10 W 206 ∼ 252V AC (50/60Hz) F 0.2A / 250V Operating Environment: Temperature : 0°C to + 40 °C (Accuracy Specified at 23 °C ± 5 °C) Temperature Coefficient : 0.1x( Specified Accuracy) per°C HUMIDITY: up to 85% RH (Relative Humidity) to 40°C without temperature extremes causing condensation within the instrument.
  • Page 10: Installation

    DANGEROUS VOLTAGE SEE EXPLANATION IN MANUAL AC-ALTERNATING CURRENT GROUND DC-DIRECT CURRENT FUSE 2. INSTALLATION 2-1. Initial Inspection This instrument was carefully inspected both mechanically and electrically before shipment. It should be physically free of damage. To confirm this, the instrument should be inspected for physical damage which may have occurred in transit.
  • Page 11: Operation

    Allow at least 30 minutes for the unit to warm up so that it can stabilize. 3. OPERATION 3-1 Voltage Measurement Voltage is the difference of electrical energy (potential) between two points. Measuring voltage allows you to verify the following questions. Is voltage present? The presence of voltage tells you that the circuit is delivering voltage to the component you are testing.
  • Page 12: Resistance Measurement

    ALWAYS START WITH THE HIGHEST RANGE FOR UNKNOWN CURRENT. THE “mA INPUT” TERMINAL IS PROTECTED BY A 2000mA/250V F TYPE FUSE AND “A INPUT” TERMINAL IS FUSED WITH 15A/250V T TYPE. WARNING MAKE SURE OF NO POWER BEFORE DISCONNECTING CIRCUIT. EVEN SMALL AMOUNT OF CURRENT CAN BE DANGEROUS.
  • Page 13: Diode Measurement

    ENERGIZED CIRCUITS ONLY. COMPLETELY DE-ENERGIZE THE CIRCUIT OR DEVICE WHICH IS TO BE MEASURED. POWER TO THE CIRCUIT UNDER TEST MUST BE OFF AND ANY CAPACITORS SHOULD BE DISCHARGED. IF AN EXTERNAL VOLTAGE IS PRESENT ACROSS A COMPONENT, IT WILL CAUSE ERRONEOUS RESISTANCE READING.
  • Page 14: Maintenance

    NOTE ; The digit error (less than 5digits) is added in measuring value. To compensate this error, check the digit error by shorting test leads(+,-) before measuring unknown frequency and deduct this value from measuring value. 4. MAINTENANCE CAUTION IT IS ESSENTIAL FOR SAFETY TO PROPERLY MAINTAIN AND SERVICE THIS INSTRUMENT WARNING VOLTAGES WITHIN THIS INSTRUMENT ARE SUFFICIENTLY HIGH TO...
  • Page 15 reason, dry the instrument using low-pressure clean air at less than 25 PSI. Use care and caution around the window cover areas where water or air could enter into the instrument while drying. Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its product and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from the data of purchase.
  • Page 16 from state-to-state. Model Number: ______________ Date Purchased:__________ Service Information Warranty Service: Please return the product in the original packaging with proof of purchase to the below address. Clearly state in writing the performance problem and return any leads, connectors and accessories that you are using with the device. Non-Warranty Service: Return the product in the original packaging to the below address.
  • Page 17 Email: service@bkprecision.com Include with the instrument your complete return shipping address, contact name, phone number and description of problem. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 TEL: 714-921-9095...
  • Page 18 PN: 481-532-9-001 Printed in Korea ©2004 B&K Precision Corp.

Table of Contents