Fitting Up And Removing The Handle - Dometic miniCool DS 200 Operating Instructions Manual

Hide thumbs Also See for miniCool DS 200:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Place back the forehead panel,rosette and screw in
reverse sequence.
11. Fitting up and removing the
handle
(If available)
The handle which can be found among the
accessories of the appliance should be fitted and
removed as follows:
11.1. Fitting up the handle
11.2. Removing the handle
12. Customer service
Before you call a service engineer, carry out the
following simple tests:
Problem
The appliance does not cool sufficiently
The appliance does not cool at all and the
LEDs are flashing
The appliance does not cool at all and
there is no lighting at all
When checking all the above points and the
refrigerator is still not working satisfactorily, contact
your nearest service engineer. State the problem,
model, product- and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.
www.dometic.com
13. Putting into operation
Technical data:
Model
DS 200
Type
DS20-60
Gross volume
22,5 litre
Mains operation
220 - 240V (AC)
Input
65W
Energy consumption 0.74 kWh/24h
Climate class
SN
Absorber Solution
147g H
13.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
(fig. 12., 13.)
(fig. 14.)
Thermostat control is set too low.
Too much food to be cooled was put in.
Door is not shut properly.
Internal air circulation is restricted.
CUC system stopped the operation.
Plug is not connected to the mains socket properly
There is no voltage in the mains socket.
DS 300
DS20-60
28,1 litre
220 - 240V (AC)
65W
0,76 kWh/24h
SN
O + 98 g NH
151g H
O + 101 g NH
2
3
2
Possible cause
DS 400
DS20-60
36,7 litre
220 - 240V (AC)
65W
0.8 kWh/24h
SN
151g H
O + 101 g NH
3
2
3
Electrical Requirements
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
appliance rating plate.
Only for UK:
The appliance is supplied with a 3 amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 3 amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
Solution
Set to a higher position.
Put in less food to be be cooled.
Check if the door is shut.
Provide inside cool air circulation.
See operating instruction 5.3.
Check if the connection is proper.
Check if there is voltage.
DS 600
DS20-60
52,6 litre
220 - 240V (AC)
85W
0.88 kWh/24h
SN
157g H
O + 105 g NH
2
3
GB