Installation
1. Install o-ring (20) and transducer (86) in filter
base (67). Torque to 35-45 ft-lb (47-61 N•m).
Install grommet onto transducer (86) and
transducer into control box.
40
67
86
20
ti13496a
2. Connect transducer connector (E) to motor
control board (95).
E
ti12999a
32
3. Install control box (61) and control panel (68)
ti7447a
4. Connect potentiometer connector (C) to motor
95
5. Install cover (96) with four screws (38).
with four screws (39).
39
ti13494a
61
control board.
C
96
38
Pressure Control Board
ti7458a
68
ti12997a
ti13493a