The Liquid Coffee Chilled Dispenser delivers two types of coffee plus hot water. The dispenser can be set up
for continuous draw (by the cup) for self-serve applications, or portion-control to fill carafes and decanters for
wait staff.
Refer to Data Plate on the dispenser, and local/national electrical code to determine circuit requirements.
WARNING - If the power cord is ever damaged, it must be replaced by the manufacturer or its service agent with
a special cord available from the manufacturer or its service agent in order to avoid a hazard.
The 120V LCC-2 LP dispenser is supplied with a 120-volt / 15 Amp cord set and require a 2-wire, grounded,
individual branch circuit rated for 120 volts AC, 15 amp, single phase, 60Hz. The mating connector must be a
NEMA 5-15R.
The LCC-2A LP dispenser is supplied with a 230-volt / 16 Amp cord set.
The 208-240V LCC-2 LP dispenser is not supplied with a cord set. It requires a 2-wire, grounded, individual
branch circuit rated for 208-240 volts AC, 20 amp, single phase, 60Hz.
The dispenser may be connected to a cold or hot water system (140°F Max.) with operating pressure between
20 and 90 psi (138 and 620 kPa) from a 3/8" or larger supply line. A shut-off valve should be installed in the line
before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to
50 psi (345 kPa). The water inlet fitting is 1/4" flare. Dispensers set up to deliver to 47.3 ml/sec (1.6 Oz./sec.)
and require a water supply source that can deliver a minimum of 1.7 gpm (6.4 lpm) at the inlet fitting.
NOTE: Bunn-O-Matic recommends 1/4" tubing from the 3/8" water supply line. At least 18 inches of FDA approved
flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate
movement to clean the counter top. It can be purchased direct from Bunn-O-Matic (part number 00326.0000).
Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the
hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanita-
tion Manual of the Food and Drug Administration (FDA). For models installed outside the
U.S.A., you must comply with the applicable Plumbing/Sanitation Code for your area.
BUNN recommends the use of our Easy Clear
Filter Kit - Easy Clear EQ-11-TL Bunn-O-Matic part no. 30344.1001

INTRODUCTION

ELECTRICAL REQUIREMENTS

L2 RED
L1 BLACK
208-240V Models

PLUMBING REQUIREMENTS

Water Quality Systems to assure perfect taste.
®