Samsung FH070EAV Servise Manual page 17

Hide thumbs Also See for FH070EAV:
Table of Contents

Advertisement

3-2 Oudoor Display Error and Check Method
Outdoor Error Display and Check Method
Inverter LED
MAIN
7-Segment
Yellow Green
-
-
-
3-2
Content
Red
Power OFF/VDD NG
Normal Operation
Indoor unit communication
error(1min.)
Communication time-out
error(2min.)
Indoor temperature sensor
Indoor unit EVA IN sensor
Indoor unit EVA OUT sensor
Dismount of indoor unit
EVA IN sensor
Dismount of indoor unit
EVA OUT sensor
Secondary detection of
indoor floating switch
Indoor fan error
Indoor eeprom error
Indoor eeprom option error
POWER ON RESET(1SEC)
Measures
• Check the input power line(AC)
• Check the LED of Main PCB and Inverter PCB
-
• Check the communication line for indoor units
• Check the power supply of the communication
phase(DC)
• Check the communication line for indoor units
• Check the power supply of the communication
phase(DC)
• Check the temp. sensor of the indoor unit room
• Check the indoor PCB connector
• Check the indoor unit drainage pipe sensor
• Check the indoor PCB connector
• Check the indoor unit drainage pipe sensor
• Check the indoor PCB connector
• Check the drainage pipe has been dismounted
• Check the drainage pipe has been dismounted
• Check the indoor unit's float sensor
• Check the indoor PCB connector
• Check the indoor PCB connector
• Check the EEPROM data
• Check the indoor's option
• Check the EEPROM data
• Check the indoor's option
-
Product operation status in
case of error
Outdoor unit
Number of
compressor/
Times
outdoor unit
fan
-
-
-
-
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
1 Time
Operation-off
-
-
Samsung Electronics