Safety Information; Installation Requirements; Important Note - Commonwealth Of Massachusetts - Nordyne TE Series 95 Installation Instructions Manual

Gas fired central furnaces
Table of Contents

Advertisement

SAFETY INFORMATION

1.
Use only with type of gas approved for this
furnace. Refer to the furnace rating plate.
2.
Install this furnace only in a location and
position as specifi ed on Tables 1 and 2 of
these instructions.
3.
Provide adequate combustion and ventila-
tion air to the furnace space as specifi ed
on Pages 10 through 14.
4.
Provisions for adequate clearances around
the vent air intake terminal(s) as specifi ed
on Figures 13 through 17 of these instruc-
tions.
5.
Combustion products must be discharged
outdoors. Connect this furnace to an ap-
proved vent system only, as specifi ed on
Pages 14 through 22.
6.
Never test for gas leaks with an open fl ame.
Use a commercially available soap solution
made specifi cally for the detection of leaks
to check all connections, as specifi ed on
Page 25 of these instructions.
7.
Always install furnace to operate within the
furnace's intended temperature-rise range
with a duct system which has an external
static pressure within the allowable range,
see furnace rating plate.
8.
When a furnace is installed so that supply
ducts carry air circulated by the furnace
to areas outside the space containing the
furnace, the return air shall also be handled
by duct(s) sealed to the furnace casing and
terminating outside the space containing the
furnace.
9.
A gas-fi red furnace for installation in a resi-
dential garage must be installed as specifi ed
on Page 7 of these instructions.
10. The furnace is not to be used for temporary
heating of buildings or structures under
construction.
Model
High Fire
Low Fire
Number
Furnace
Furnace
*TE060
60,000
42,000
*TE080
80,000
56,000
*TE100
100,000
70,000
*TE120
120,000
84,000
Table 1. Furnace Dimensions and Shipping Weights
4

INSTALLATION REQUIREMENTS

Requirements and Codes
This furnace must be installed in accordance with
these instructions, all applicable local building
codes, and the current revision of the National
Fuel Gas Code (ANSI-Z223.1, NFPA-54). The
current revision of the National Fuel Gas Code
is available from:
Canada installations shall comply with CAN/
CGA-B149 installation codes, local plumbing
or waste water codes and other applicable
codes.
Additional helpful publications are:
• NFPA-90A - Installation of Air Conditioning
• NFPA-90B - Warm Air Heating and Air
These publications are available from:
This furnace is not approved for instal-
lation in mobile homes. Installation
in a mobile home could cause fi re,
property damage, and/or personal
injury.
IMPORTANT NOTE
The Commonwealth of Massachusetts re-
quires compliance with regulation 248 CMR
4.00 and 5.00 for installation of through – the
– wall vented gas appliances as follows:
Temperature Rise Range,
°F
1st Stage
2nd Stage
35-65
35-65
30-60
30-60
40-70
40-70
45-70
45-75
American National Standards Institute, Inc.
1430 Broadway
New York, New York 10018
and Ventilating Systems.
Conditioning Systems.
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, Massachusetts 02269
WARNING:
Dimensions (inches)
A
B
C
19 3/4
18 1/4
7 7/8
19 3/4
18 1/4
7 7/8
19 3/4
18 1/4
7 7/8
22 1/2
21
9 1/4
Shipping
Weight
(lbs)
D
17 1/4
195
17 1/4
195
17 1/4
200
20
220