airfl ow rate for the capacity. Detailed operation is
described in the cooling unit installation instruc-
tions and control manual.
Verifying and Adjusting
Temperature Rise
Verify that the temperature rise through the
furnace is within the range specifi ed on the
furnace rating plate. Temperature rises outside
the specifi ed range could result in premature
heat exchanger failure.
Place temperature measuring device in the return
and supply air stream as close to the furnace
as possible. The device on the supply air side
must be shielded from direct radiation from the
heat exchanger to avoid false readings. Adjust
all registers and duct dampers to the desired
position and run the furnace for fi fteen minutes
before taking any temperature readings. The
temperature rise is the difference between the
supply and return air temperatures.

Verifying Burner Operation

To verify operation of the burners, make sure
that the blower compartment door is in place
and that there is power to the furnace. Set
GAS FLOW RATE (CUBIC FEET PER HOUR)
CUBIC FEET PER REVOLUTION OF
TIME FOR
METER
ONE REVOLUTION
(SECONDS)
1
24
150
26
138
28
129
30
120
32
113
34
106
36
100
38
95
40
90
42
86
44
82
46
78
48
75
50
72
52
69
54
67
56
64
58
62
60
60
62
58
64
56
66
55
68
53
70
51
72
50
the thermostat above room temperature and
observe the ignition sequence. The fl ame can
be observed through the small clear window
on the burner box. The fl ames should be blue,
without yellow tips. Flames should extend from
each burner without lifting, curling, or fl oating.
After verifying ignition, set the thermostat below
room temperature and verify that the burner fl ame
extinguishes completely.
Verifying Operation of the Supply
Air Limit Switch
To verify operation of the supply air limit switch,
make sure that the blower door is in place and
that there is power to the furnace. Completely
block the return airfl ow to the furnace by install-
ing a close-off plate in place of or upstream
of the fi lter(s). Set the thermostat above room
temperature and verify that the Sequence of
Operation is as described in these instructions.
The supply air limit switch should function to
turn off the gas valve within approximately fi ve
minutes. The circulating air and combustion blow-
ers should continue to run when the supply air
limit switch opens. Remove the close-off plate
immediately after the supply air limit switch opens.
If the furnace operates for more than fi ve minutes
with no return air, set the thermostat below room
TIME FOR
ONE REVOLUTION
(SECONDS)
5
10
750
1500
692
1385
643
1286
600
1200
563
1125
529
1059
500
1000
474
947
450
900
429
857
409
818
391
783
375
750
360
720
346
692
333
667
321
643
310
621
300
600
290
581
281
563
273
545
265
529
257
514
250
500
Table 11. Gas Flow Rate
CUBIC FEET PER REVOLUTION OF
METER
1
74
49
76
47
78
46
80
45
82
44
84
43
86
42
88
41
90
40
92
39
94
38
96
38
98
37
100
36
102
35
104
35
106
34
108
33
110
33
112
32
114
32
116
31
118
31
120
30
5
10
243
486
237
474
231
462
225
450
220
439
214
429
209
419
205
409
200
400
196
391
191
383
188
375
184
367
180
360
176
353
173
346
170
340
167
333
164
327
161
321
158
316
155
310
153
305
150
300
29