Indoor Unit Installation

1.

Installing the mounting plate

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the unit is completely level, and mark the boring points
on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
Use tape measure
as shown.
Position the end of
tape measure at ∇.
Drain hose
position
2.

Boring a wall hole and installing wall embedded pipe

• For walls containing metal frame or metal board, be sure to use a
wall embedded pipe and wall cover in the feed-through hole to
prevent possible heat, electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to
prevent water leakage.
1) Bore a feed-through hole of 65mm in the wall so it has a down
slope toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk
pipe hole gap with putty.
3.
Inter-unit wiring
1) Open the front panel, then remove the service lid.
2) Pass the inter-unit wire from the outdoor unit through the
feed-through wall hole and then through the back of the
indoor unit. Pull them through the front side. Bend the
ends of tie wires upward for easier work in advance. (If
the inter-unit wire ends are to be stripped first, bundle
wire ends with adhesive tape.)
3) Press the bottom frame of the indoor unit with both
hands to set it on the mounting plate hooks. Make sure
the wires do not catch on the edge of the indoor unit.
IEnglish
Recommended mounting plate
retention spots (7 spots in all)
200
(Bolt size: M10)
φ65
100
135
302
Through-the-wall hole φ65mm
Place a leveler on raised tab.
(Bolt size: M10)
Gas pipe end
50
Liquid pipe end
915
Inside
Wall embedded pipe
(field supply)
Wall hole cover
(field supply)
Hang indoor unit's hook here.
When stripping the ends of inter-unit
wire in advance, bind right ends of
wires with insulating tape.
260
φ65
160
110
unit: mm
Outside
Caulking
Wall embedded pipe
(field supply)
A Mounting plate
Inter-unit
wire
8