Download Print this page

Technical Data Sheet; Tumble Dryer - Miele PT 8803 EL Installations Plan

Advertisement

Available languages

Available languages

Technical datasheet

Tumble dryer:

Heating:
Legend:
Optional extras:
Concrete plinth
Quality and density of concrete must comply with load.
BS
Concrete plinth must be firmly secured to floor!
Recommended height
Minimum height
Width min.
Width:min.
Machine connections:
Electrical
1. Standard voltage (as supplied)
connection
2. Standard voltage (as supplied)
Non-standard voltages:
OS 440
Standard voltage (as supplied)
Electrical connection must comply with national regulations.
Connection using multi-pole wall socket in compliance with
IEC/EN 60309 and IEC/EN 60947 is recommended in order to
simplify electrical tests.
If machines are hard-wired, a multi-pole mains switch must be
provided on site.
A wall socket or mains isolator must be accessible after
installation.
Installationsplan / Installation plan: PT 8803/8805/8807
Datum / Date: 12.01.2011
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Cable screw connector
Connection cable (to be ordered separately)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Cable screw connector
Connection cable (to be ordered separately)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Cable screw connector
Connection cable (to be ordered separately)
PT 8803/8805/8807
Electric (EL)
en - GB
mm
100
mm
50
mm
1200
mm
1400
V
3N AC 380 - 415
Hz
50
kW
34.4 – 40.7
A
3 × 63
mm²
5 × 16
M 50
V
3 AC 220 - 240
Hz
50
kW
34.8 – 41.1
A
3 × 100
mm²
4 × 25
M 50
V
3 AC 440
Hz
60
kW
37.9
A
3 × 63
mm²
4 × 16
M 40
Seite / Page: 9

Advertisement

loading

This manual is also suitable for:

Pt 8807 elPt 8805 el