Maintenance (continued)
CHECKING THE OIL
WARNING: Drain the tank to release air pressure before
removing the oil fill cap or oil drain plug.
CAUTION: Overfilling with oil will cause premature air
compressor failure. Do not overfill.
NOTICE: Risk of property damage. Use air compressor oil only.
Multi-weight automotive engine oils like 10W30 should not be use in
air compressors. They leave carbon deposits on critical components,
thus reducing performance and compressor life.
The oil level should be to the middle of the sight
glass (3).
If needed remove the oil fill plug (1) and slowly
add oil until it reaches the middle of the sight
glass.
NOTE: Use 30W compressor oil or a heavy duty SAE
30W, non-detergent, SF grade or better oil. Do not use
multi-weight automotive engine oils, as they will reduce
compressor life. Under extreme winter condition use SAE-10
weight oil.
CHANGING THE OIL
Remove the oil fill plug (1).
Remove the oil drain plug (2) and drain the oil
into a suitable container.
Replace the oil drain plug (2) and tighten
securely.
Slowly add compressor oil until it reaches the
middle of the sight glass (3).
NOTE: Crankcase oil capacity is approximately 10.6 fluid
ounces (313,5 ml).
NOTE: When filling the crankcase, the oil flows very slowly
into the pump. If the oil is added too quickly, it will overflow
and appear to be full.
Replace the oil fill plug (1) and tighten securely.
C302H_HUSKY_manual_5-15-ENG.indd 19
3
2
19
Please contact 1-888-43-HUSKY for further assistance.
1
HUSKYTOOLS.com
6/10/15 12:05 PM