12. Selecting the Spray Setting
(Wall Extra I-Spray spray attachment)
WARNING! Danger of injury! Never pull the trigger guard while adjusting
the air cap.
2 different spray jet shapes can be set by turning the adjustment ring (fig. 8, 1)
Fig. 9 A = vertical flat jet
Fig. 9 B = horizontal flat jet 
Use the red adjustment lever to also switch between a wide ( )
and a narrow (
) spray jet.

13. Adjusting the Material Volume (Fig. 10)

Set the material volume by turning the regulator on the trigger guard of the spray gun.
- turn to the left
+ turn to the right 

14. Setting the Amount of Air (Fig. 11)

Depending on the viscosity of the material to be sprayed and the finish of the object to be
coated, it may be advisable to vary the amount of air. Very low viscosity materials, such as
watery glazes do not have to be atomised with the maximum amount of air. In this case it
is advisable to reduce the amount of air and thus minimize the spray vapour.
This also applies for the use of the Detail and Corner&Reach spray attachment (accessory).
- turn to the right
+ turn to the left
for horizontal surfaces
for vertical surfaces
lower material volume
higher material volume
 lower amount of air
 higher amount of air