Adjustment Procedure; Basic Adjustments; Electrical Adjustments - Toshiba MV19K2 Service Manual

Color television/video cassette recorder
Hide thumbs Also See for MV19K2:
Table of Contents

Advertisement

1. ADJUSTMENT PROCEDURE

Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.
CAUTION
When replacing IC's or transistors, use only specified
silicon grease.
(To prevent the damage to IC's and transistors.)
On-Screen Display Adjustment
1.
Unplug the AC plug for more than 5 seconds to set the
clock to the non-setting state. Then, set the volume
level to minimum.
2.
Press the VOL. DOWN button on the set and the
channel button (9) on the remote control simultaneously
to display adjustment mode on the screen as shown in
Fig. 1-1.
NOTE
Use the channel buttons (1-8) on the remote control to
select the options shown in Fig. 1-1.
Press the channel button (0) on the remote control to
end the adjustments.
1. H/V
2. AKB
3. COLOR TEMP
4. PICTURE
5. OTHERS
6. TEST PATTERN
7. STEREO/SAP
8. (VOL TEST)

2. BASIC ADJUSTMENTS

(VCR SECTION)
2-1: PG SHIFTER
1.
Connect CH-1 on the oscilloscope to TP1002 and CH-2
to TP4201.
2.
Playback the alignment tape.
3.
Press and hold the Tracking-Auto button on the remote
control more than 2 seconds to set tracking to center.
4.
Press the VOL. DOWN button on the set and the
channel button (3) on the remote control simultaneously
until the indicator REC disappears. If the indicator REC
disappears, adjustment is completed.
(If the above adjustments doesn't work well:)
5.
Press the VOL. DOWN button on the set and the
channel button (3) on the remote control simultaneously
until the indicator REC disappears.
6.
When the REC indicator is blinking, press both VOL.
DOWN button on the set and the channel button (4) on
the remote control simultaneously and adjust the
Tracking +/- button until the arising to the down of Head
Switching Pulse becomes 6.5 ± 0.5H.
(Refer to Fig. 2-1-A, B)
7.
Press the Tracking Auto button.

ELECTRICAL ADJUSTMENTS

0. END
Fig. 1-1
6.5H
6.5H
2-2: RF AGC
1.
Receive the monoscope pattern.
2.
Connect the digital voltmeter between the pin 5 of
CP603 and the pin 1 (GND) of CP603.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (5) on the remote control.
The Fig. 2-2 appears on the display.
4.
Press the channel button (1) on the remote control.
5.
Press the VOL. UP/DOWN button on the remote control
until the digital voltmeter is 2.3 ± 0.05V.
1. RF AGC DELAY
2. VIDEO LEVEL
3. FM LEVEL
4. OSD H
5. CUT OFF
6.
7.
8.
2-3: VCO FREERUN
1.
Place the set with Aging Test for more than 15 minutes.
2.
Receive the UHF.
3.
Disconnect the Antenna while receiving the UHF and
set to the Noise screen.
4.
Once turn off the Power and turn on the Power again.
5.
Approxi. 3 seconds later, input the Antenna again.
6.
Connect the digital voltmeter to TP601.
Adjust the L610 until the digital voltmeter is 3.1 ± 0.05V.
7.
(TV SECTION)
2-4: CONSTANT VOLTAGE
1.
Using the remote control, set the brightness and
contrast to normal position.
2.
Connect the digital voltmeter to TP401.
3.
Set condition is AV MODE without signal.
Adjust the VR502 until the DC voltage is 135 ± 0.5V.
4.
CH-2
CH-1
Fig. 2-1-A
CH-2
CH-1
Fig. 2-1-B
0. RETURN