15.0 Changing Components
15.5
Burner (Fig. 55)
1. Remove the clip securing the gas feed pipe to the air/gas
venturi and disconnect the fan electrical plugs.
2. Undo the screws securing the collector to the cover
(33/40 kW models) or extension piece (28 kW model).
Remove this extension piece from the cover (on 28 kW
models).
3. Withdraw the burner from the cover and replace with
the new one.
4. Examine the gasket(s), replacing if necessary.
5. Reassemble in reverse order.
15.6
Insulation (Fig. 56)
1. Remove the clip securing the gas feed pipe to the venturi
and disconnect the fan electrical plugs.
2. Remove the electrodes as described in section 15.2.
3. Undo the nuts holding the cover to the heat exchanger.
Draw the air/gas collector, fan and cover assembly away.
4. Remove the cover insulation piece.
5. Fit the new insulation carefully over the burner and align
it with the slots for the electrodes.
6. If the rear insulation requires replacement, remove it and
all debris from the heat exchanger. Also it may be necessary
to separately remove the spring clip from the pin in the
centre of the heat exchanger and the 'L' shaped clips
embedded in the insulation.
7. Do not remove the shrink-wrapped coating from the
replacement rear insulation. Keep the insulation vertical and
press firmly into position.
8. Examine the cover seal and replace if necessary.
Reassemble in reverse order.