9.2.

Initialization Pulse Adjust

1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
· · · · Picture menu: Standard
· · · · Color temperature : Middle
· · · · Picture : 25
3. Connect Oscilloscope to TPSC1 (T1) and check for 15±10µ Sec.
4. Connect Oscilloscope to TPSC1 (T2) and adjust R6557 for 184+5µ /-10µ Sec.
Test point
T1
TPSC1 (SC)
T2
TPSC1 (SC)
R6557 (SC)
Volume
Level
---
15 ± 10µ Sec
184 + 5µ / - 10µ Sec