Rinnai REU-KM2035FFUD-E Installation And User Manual page 31

Flow water heater
Table of Contents

Advertisement

FLUE REQUIREMENTS
BS5440—1
Symbol
Directly below an opening, air brick, opening windows, ect.
A
Above an opening, air brick, opening window, ect.
B
Horizontally to an opening, air brick, opening window, ect.
C
Below plastic gutters, soil pipes, drain pipes, ect.
D
E
Below eaves
F
Below balconies or car port roof
G
From vertical drain pipe or soil pipe
H
From and internal or external corner
Above ground, roof or balcony level
I
From surface facing the terminal
J
From terminal facing terminal
K
From opening in the car port (eg door, window ect) into the dwell-
L
Vertically from terminal on the same wall
M
Horizontally from terminal on the same wall
N
O
From the wall on which the terminal is mounted
P
From a vertical structure on the roof
Above intersection with the roof
Q
BS5440—1
Terminal Position
31
Dimen-
sion
300mm
300mm
300mm
75mm
200mm
200mm
150mm
300mm
300mm
600mm
1200mm
1200mm
1500mm
300mm
0
N/A
300mm