TEMPERATURE CONTROLS
Remote temperature controllers provide control over the water temperature. Rinnai water
heaters can be operated with 1, 2, 3, 4 or no temperature controllers.
Each time a button is pressed, a BEEP will sound. The BEEP sound can be
muted by depressing the Temperature Controller Up and Down buttons
simultaneously for more than 3 seconds. This can be done for each
Temperature Controller. To return to original settings, repeat this step.
NOTE
Safety features
Whilst
the hot water tap is open, the
following safety features apply:
Temperature
selection
transferred.
The temperature set point on the
controller with priority can always be
lowered, but the set point can only be
raised to 43°C.
Other controllers are unable to take
priority
or
change
temperature of the water.
If off, the controller cannot be turned on.
NOTE
cannot
be
hot water rises to more than 3ºC above the
selected temperature shown on the digital
display, or the pre-set limit if controllers are
not fitted, the burner will automatically go
out.
The red operation indicator will also go out.
the
delivery
The burner will ignite again once the
outgoing hot water temperature falls to that
shown on the digital display (or the pre-set
limit of the Rinnai Infinity heater).
10
The temperature of the outgoing
water is constantly monitored by
a built in sensor.
If the temperature of the outgoing

Hide quick links:

Advertisement