Servicing Mode; Auto Switch Operation; Indicator Panel - Panasonic CS-E9HKEA Service Manual

Hide thumbs Also See for CS-E9HKEA:
Table of Contents

Advertisement

13 Servicing Mode

13.1. Auto Switch Operation

The below operations will be performed by pressing the "AUTO" switch.
1. AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto Switch is pressed and release before 5 sec..
2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to below 8 sec..
A "beep" sound will occur at the fifth sec., in order to identify the starting of Test Run operation.
3. HEATING TRIAL OPERATION
Press the AUTO switch continuously for more than 8 sec. to below 11 sec. and release when a "beep, beep" sound is heard at
eight sec. (However, a "beep" sound is occurred at fifth sec.) then press remote controller "A/C Reset" button once. Remote
controller signal will activate operation to force heating mode.
4. REMOTE CONTROLLER RECEIVING SOUND ON/OFF
The ON/OFF of remote controller receiving sound can be change over by following steps:
a. Press the AUTO switch continuously for more than 16 sec. to below 21 sec. a "beep, beep, beep, beep" sound will occur
at the sixteenth sec..
b. Press the "A/C Reset" button once. Remote controller signal will activate the remote controller sound setting mode.
c. Press the "Check" button once at remote controller. A "beep" sound will occur.
d. Press the AUTO switch once to select remote controller receiving sound ON/OFF. A "beep" sound indicates receiving
sound ON, and a long "beep" sound indicates receiving sound OFF.

13.2. Indicator Panel

LED
POWER
Color
Green
Light ON
Operation ON
Light OFF
Operation OFF
Note:
• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode judgment, or
ON timer sampling.
• If Timer LED is blinking, there is an abnormality operation occurs.
• If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.
TIMER
QUIET
Orange
Orange
Timer Setting ON
Quiet Mode ON
Timer Setting OFF
Quiet Mode OFF
POWERFUL
Orange
Powerful Mode ON
Powerful Mode OFF
34
ION
ALLERGEN BUSTER
Green
Blue
Ion Mode ON
Operation ON
Ion Mode OFF
Operation OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-e9hkeaCs-e12hkeaCu-e12hkea

Table of Contents