Relationship Between The Condition Of The Air Conditioner And Pressure And Electric Current; Breakdown Self Diagnosis Function - Panasonic CS-E9HKEA Service Manual

Hide thumbs Also See for CS-E9HKEA:
Table of Contents

Advertisement

14.2. Relationship Between The Condition Of The Air Conditioner And
Pressure And Electric Current
Condition of the air conditoner
Insufficient refrigerant
(gas leakage)
Clogged capillary tube or Strainer
Short circuit in the indoor unit
Heat radiation deficiency of the
outdoor unit
Inefficient compression
• Carry on the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started.

14.3. Breakdown Self Diagnosis Function

Once abnormality detected during operation, the unit will immediately stop its operation (Timer LED is blinking) and maximum of
three error codes (abnormality) will be saved in memory. The abnormality of the operation can be identified through the below
breakdown diagnosis method:
• Press "CHECK" button at remote controller continuously for more than five seconds to turn on the diagnosis mode, "H11" will be
displayed at remote controller.
• By pressing the TMER " " button once, next error code will be displayed; press "V" button once, previous error code will be
displayed.
• If error code displayed matches the error code saved in unit memory (abnormality detected), "beep, beep, beep...." sounds will
be heard for 4 seconds and Power LED will light on. Otherwise, one "beep" sound is heard.
If "CHECK" button is press again or without any operation for 30 seconds, the diagnosis mode will turn off.
Cooling Mode
Low Pressure
High Pressure
Electric current
Low Pressure
during operation
36
Heating Mode
Electric current
High Pressure
during operation