Rs-232C Status Condition Change Notifi Cation - Mitsubishi Electric DX-TL308E series Operation Manual

Hide thumbs Also See for DX-TL308E series:
Table of Contents

Advertisement

Command code table (continued)
RS-232C Status condition change notifi cation (2/2)
*: The commands marked with asterisk (*) are not available with DX-TL304E series.
Mode
Alarm
NTFY01,**
**
**
(4)
notifi cation
********
Signal detection
NTFY02,**
**
**
(n+3)
notifi cation
**
(n+8)
************
n=The number of cameras without
signal/with signal.
High temperature
NTFY03,**
**
**
(5)
detection
**
(8)
notifi cation
Fan status
NTFY04,**
**
**
(5)
notifi cation
**
(8)
Status
**
**
**
(1)
(2)
(3)
**
**
**
****
(5)
(6)
(7)
(8)
(9)
**
**
**
**
**
**
**
************
**
**
-**
**
(1)
(2)
(3)
(n+2)
**
**
**
(n+4)
(n+5)
(n+6)
(n+7)
(n+9)
**
<For DX-TL308E series> 01-08
<For DX-TL304E series> 01-04
**
**
**
**
**
**
**
************
**
**
**
**
(1)
(2)
(3)
(4)
**
**********
(6)
(7)
**
**
**
**
**
**
************
**
**
**
**
(1)
(2)
(3)
(4)
**
**********
(6)
(7)
**
**
**
**
**
**
************
(1)
:Alarm number
00:ALARM 1
01:ALARM 2
04:ALARM 5*
05:ALARM 6*
16:EMERGENCY
(2)
:Trigger
00:Rear terminal
(3)
:Year (01-37)
(4)
:Month (01-12)
(5)
:Day (01-31)
(6)
:Hour (00-23)
(7)
:Minute (00-59)
(8)
:Second (00-59)
(9)
:IP address
000.000.000.000-255.255.255.255
(1)
:Signal detection status
00:No signal detected (in the mode other then recording)
01:Signal detected (in the mode other then recording)
02:No signal detected (during recording)
03:Signal detected (during recording)
(2)
:The number of cameras without signal/with signal
(3)-(n+2)
:Camera number of which signal is detected/is not detected
(n=The number of cameras without signal/with signal.)
00:CH1
01:CH2
04:CH5*
05:CH6*
(n+3)
:Year (01-37)
(n+4)
:Month (01-12)
(n+5)
:Day (01-31)
(n+6)
:Hour (00-23)
(n+7)
:Minute (00-59)
(n+8)
:Second (00-59)
(n+9)
:IP address
000.000.000.000-255.255.255.255
(1)
:High temperature detection status
00:High temperature detected
01:High temperature warning
10:Recovery from high temperature
(2)
:Year (01-37)
(3)
:Month (01-12)
(4)
:Day (01-31)
(5)
:Hour (00-23)
(6)
:Minute (00-59)
(7)
:Second (00-59)
(8)
:IP address
000.000.000.000-255.255.255.255
(1)
:Fan status
00:Stop of fan
10:Recovery of fan
(2)
:Year (01-37)
(3)
:Month (01-12)
(4)
:Day (01-31)
(5)
:Hour (00-23)
(6)
:Minute (00-59)
(7)
:Second (00-59)
(8)
:IP address
000.000.000.000-255.255.255.255
42
Note
02:ALARM 3
03:ALARM 4
06:ALARM 7*
07:ALARM 8*
02:CH3
03:CH4
06:CH7*
07:CH8*